We are in the process of receiving our CSA approved temporary power skids - ideal for providing construction power and services for large or small sites. These mobile skids can come with dual tapped transformers (480V and 600V) so are easily wired for site power systems, as well as your typical 120/208 panels attached to them for the more common power tool, portable job shack plug ins and lighting loads. Right down to the small and easily moveable "pony panels" that would be cord connected to the larger distributions. Complete with GFCI receptacles as well as common temporary site trailer connections. Given we are still in the process of receiving and assessing the units we may require some lead time on replacing worn out or missing parts.
Unit 4625
120/240V Single Phase 200A Pony Panel
Comes with:
20 - 20A GFCI receptacles
2 - 30A 125/250V L14-30 twist lock receptacles
2 - 50A 125/250V CS6369 receptacle
This unit would need a feed cable
Unit 4626
120/240V Single Phase 100A Pony Panel
Comes with:
10 - 20A GFCI receptacles
2 - 50A 125/250V "california" cord end In and Out
Unit 4627
120/240V Single Phase 200A Pony Panel
Comes with:
20 - 20A GFCI receptacles
2 - 125/250V 30A L14-30 receptacle
2 - 125/250V 50A CS6369 receptacle
Unit 4641
120/240V Single Phase 200A Pony Panel
Comes with:
20 - 20A GFCI receptacles,
2 - 30A 125/250V L14-30 twist lock receptacles
2 - Additional 125/250V 30A L14-30 cord ends
2 - 50A 125/250V CS6369 receptacle
This unit would need a feed cable
Unit 3251
120/240V Single Phase 100A Pony Panel
Comes with:
6 - 20A GFCI receptacles
100' of feed cable with 50A "California" cord end
Unit 2932-B
600 OR 480V primary feed based on dual tapped transformer - Would need to be wired for appropriate input voltage - Cam lock connections available on primary side 200A 3P4W splitter
On primary side:
2 - 60A 3P fused disconnects
1 - 60A 3P fused disconnect with Crouse Hinds AR642 60A 3P4W receptacle
75KVA Secondary to 120/208 3P4W distribution panel
Comes with:
10 - 20A 125V GFCI receptacle
4 - 30A 3 phase twist lock L21-30 receptacle
2 - 125/250V 30A twist lock receptacle
4 - 60A 3 phase 208V Leviton pin and sleeve connection - 560R9W - receptacle - These would either be wired in, or the receptacles below - (One or the other)
4 - 125/250 50A 3 pole 4 wire grounding CS6364C cord end (California)
1 - 125/250V 30A L14-30 cord end
1 - 125V 15A cord end
Unit 65190
600 OR 480V primary feed based on dual tapped transformer - Would need to be wired for appropriate input voltage - Cam lock connections available on primary side 200A 3P4W splitter
On primary side:
2 - 60A 3P fused disconnects
1 - 60A 3P fused disconnect with ADR6034 Arc tight receptacle
75KVA Secondary to 120/208 3P4W distribution panel
Comes with:
10 - 20A 125V GFCI receptacle
6 - 30A 3 phase twist lock L21-30 receptacle
4 - 60A 3 phase 208V Leviton pin and sleeve connection - 560R9W - receptacle
Unit 1153B
600V primary feed - Cam lock connections available on primary side 200A 3P4W splitter
On primary side:
3 - 60A 3P fused disconnects
45KVA Secondary to 120/208 3P4W distribution panel
Comes with:
10 - 125V 20A GFCI receptacle
2 - 125/250V twist lock receptacles - L14-30
2 - 208 3 phase twist lock L21-30 receptacles
2 - 60A 3 phase 208V Leviton pin and sleeve connection - 560R9W - receptacles
Unit 1089B
600 OR 480V primary feed based on dual tapped transformer - Would need to be wired for appropriate input voltage - Cam lock connections available on primary side 200A 3P4W splitter
On primary side:
2 - 60A 3P fused disconnects
1 - 60A 3P fused disconnect with Crouse Hinds APR6465 cord end
75KVA Secondary to 120/208 3P4W distribution panel
Comes with:
10 - 125V 20A GFCI receptacle
2 - 208 3 phase twist lock L21-30 receptacles
4 - 125/250V 30A L14-30A receptacle and cord end
4 - 60A 3 phase 208V Leviton pin and sleeve connection - 560R9W - receptacles
2 - 125/250 50A 3 pole 4 wire grounding CS6364C cord end (California)
Unit 4295
600V primary feed - Cam lock connections available on primary side 200A 3P4W splitter
On primary side:
150KVA Secondary to 120/208 400A 3P4W distribution panel
Comes with:
20 - 125V 20A GFCI receptacle
12 - 208V 3 phase twist lock receptacles - L15-30
2 - 125/250V 30A cord end
4 - 125/250V 50A cord end CS6364C cord end (California)
Unit 4296
600V primary feed - Cam lock connections available on primary side 200A 3P4W splitter
On primary side:
150KVA Secondary to 120/208 400A 3P4W distribution panel
Comes with:
20 - 125V 20A GFCI receptacle
12 - 208V 3 phase twist lock receptacles - L15-30
2 - 208 3 phase twist lock L21-30 receptacles
2 - 60A 3 phase 208V Leviton pin and sleeve connection - 560R9W - receptacles
8 - 50A 125/250V CS8369C receptacle
6 - 50A 125/250V CS6364C cord ends
2 - 30A 125/250V L14-30 cord ends
We have a large amount of portable power cable that we can supply with the above temporary power skids from 2/0 GGC, to 350GGC. Extra heavy duty cabling typically used in mines and as trailing cable. These are all on reels in 100m lengths already, so whether you're in a pinch and need to purchase cable, or prefer to rent. We have new and used reels available. Ask us about our surplus 5KV teck cable as well. We may be able to help if you're stuck!
To go with cables above, or separately:
26 - Male - 400A 8KV sized for 2/0 cable
25 - Female - 400A 8KV sized for 2/0 cable
4 - Male - 250A 8KV sized for 2/0
1 - Female 250A 8KV sized for 2/0
6 - Male - 400A 8KV sized for 350KMIL
5 - Female - 400A 8KV sized for 350KCMIL
We can either help with bending conduit up to 4" rigid, or: we can rent you the equipment needed to bend conduit on site! We have 2 units available - 1" to 2" rigid conduit bender with pump, or 2" to 4" with pump. Each unit comes with appropriate shoes needed to properly bend any electrical conduit you have on site
Need to move something heavy through a building without wrecking the floor? We have 2 ton rated urethane wheeled skates with handles
Current tools model 615 electric cable reeler - For when you have large reels and reel jacks won't work!
LB White Tradesman K175 with 15' and 25' socks - requires 120V
12 and 15 ton hypresses and most common dies for either grounding or lugs - Burndy patriot 750 (12 ton) and 46LWSI (15 Ton). We also have an additional manual burndy MD6/MD7 crimper with W dies
Hilti TE1000 with ground rod attachments
Though we don't rent our own arc flash and shock protection PPE we use daily on HV systems, we do have additional sets of 40 calorie arc flash suits if you're in a pinch
With some of the long lead times we are seeing, we have recently picked up smaller distribution transformers that would be available for rent if your energization date is ahead of delivery date on the permanent units.
1 - 480V 3P3W to 120/208 3P4W - 75KVA indoor
1 - 600V 3P3W to 120/208 3P4W - 150KVA indoor
3 - 600V 3P3W to 120/208 3P4W - 45KVA outdoor rated
1 - 600/347V 3P4W to 480/277 3P4W - 75KVA outdoor rated
1 - 600V 1P2W to 120/240 1P3W - 15KVA indoor rated
Although we may be a bit before we can sort our rentals out, we are always happy to help with what we've got on hand. Inquire anyways!
We have a small crew so all of us are handling multiple aspects of the company, so though we don't have things posted as ready, we may be able help ahead of having everything posted!
26 - Male - 400A 8KV sized for 2/0 cable
25 - Female - 400A 8KV sized for 2/0 cable
4 - Male - 250A 8KV sized for 2/0
1 - Female 250A 8KV sized for 2/0
6 - Male - 400A 8KV sized for 350KMIL
5 - Female - 400A 8KV sized for 350KCMIL
We use cookies to analyze website traffic and optimize your website experience. By accepting our use of cookies, your data will be aggregated with all other user data.